E1041 and E1061 display
The E1041 and E1061 operator panel is developed to satisfy the demands of human-machine
communication. Built-in functions such as displaying and controlling text, dynamic
indication, time channels, alarm and recipe handling are included.
-
Cabin Unit
Cabin Unit is the terminal device of the air conditioning system, which are applicable for the lodging cabins, dining halls, offices, meeting rooms and so on in the vessels, which can also be used as the terminal device of the hotels, hospitals, large meeting halls, etc.
-
Refrigerant dryer
All ELIMINATOR® driers have a solid core with binding material held to an absolute minimum.
There are two types of ELIMINATOR® cores. Type DML driers have a core composition of 100% Molecular Sieve, while type DCL contain 80% Molecular Sieve with 20% activated alumina.
-
Sight glass
Sight glasses are used to indicate:
1. The condition of the refrigerant in the plant liquid line.
2. The moisture content in the refrigerant.
3. The flow in the oil Return line from the oil separator.
The SGI, SGN, SGR or SGRN can be used for CFC, HCFC and HFC refrigerants. -
Solenoid valve and coil
EVR is a direct or servo operated solenoid valve for liquid, suction, and hot gas lines with fluorinated refrigerants.
EVR valves are supplied complete or as separate components, i.e. valve body, coil and flanges, if required, can be ordered separately. -
Stop and regulating valves
SVA shut-off valves are available in angleway and straightway versions and with Standard neck (SVA-S) and Long neck (SVA-L).
The shut-off valves are designed to meet all industrial refrigeration application requirements and are designed to give favourable flow characteristics and are easy to dismantle and repair when necessary.
The valve cone is designed to ensure perfect closing and withstand a high system pulsation and vibration, which can be present specifically in the discharge line. -
Strainer
FIA strainers are a range of angleway and straightway strainers, which are carefully designed to give favourable flow conditions. The design makes the strainer easy to install, and ensures quick strainer inspection and cleaning.
-
Temperature Controls
The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single phase AC motor of up to approx. 2 kW or installed in the control circuit of DC motors and large AC motors.
-
Temperature transmitter
Pressure transmitters type EMP 2 convert pressure to an electric signal.
This is proportional to, and linear with, the value of the pressure to which the pressure-sensitive element is subjected by the medium. The units are supplied as two-wire transmitters with an output signal of 4- 20 mA.
The transmitters have a zero-point displacement facility for equalizing static pressure.
-
Expansion valve
Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat.
Therefore the valves are especially suitable for liquid injection in “dry” evaporators where the superheat at the evaporator outlet is proportional to the evaporator load.
-
Pressure controls
KP pressure switches are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure.
-
Pressure gauge
This series of pressure gauges is well suited for application in the refrigeration industry. The differential pressure gauge is specifically intended for stamping compressors for measuring suction and oil pressure.