• sns01
  • sns02
  • sns03
whatsapp instagram wechat
FairSky

Marine cooling and heating Air handling Unit

Short Description:

The MAHU Marine air handling units have been designed to fit all marine applications. All parts are to be considered the “state of the art” in this field. A long practical experience is behind this product and a lot of world wide applications prove the high quality reached in the manufacturing of these units. All the installations are made according to the main Marine Registers and almost all units have been tested under extreme conditions experienced in the marine environment.


Product Detail

Product Tags

Description

MAHU marine air handling unit is the important device to deal with the temperature and humidity of the air in the cabin. Normal AHU parts consist of the following sections, which can be freely combined and mounted in casings to form complete sections: mixing air intake, filter section, heating section, cooling section, humidifying section, fan section, discharge section.

The supporting framework is made of extruded anodised aluminium and assembled by means of reinforced nylon corner joints, to get a strong and rigid structure. The double-skinned panels are internally insulated with a high effificiency, mineral wool insulation (60 kg/m3 density and more for special purpose), standard panels are in Aluzinc® and are manufactured in 25 mm or 45 mm, thickness.

Features

● Packaged framework and panels are main and special structure for the unit.
● The panels are 50 mm thick and consist of a double skinned steel sheet with intermediate mineral wool. Alu-Zinc steel or Stainless Steel is available for panel material.
● Good acoustic and thermal insulation for the unit.
● Hard fastness between panels and frame to ensure good air tightness.
● The spiroduct air pipe can be connected directly to the sections for easy installation.
● The access doors are available, which can be opened and detached easily for inspection and servicing.
● The functional sections are optional for customers, and meet the most demanding requirements.

AHU-3
AHU-4

Technical Data

Item AHU Type MAHU 1006 1009 1406 1409 1413 1909 1911 1913 1916
Max Air flows m3/s 1.18 1.74 1.83 2.69 4.17 3.99 5.08 6.16 7.98
m3/h 4250 6250 6600 9690 15000 14360 18270 22180 28730
External(3) Static pres. Pa 1550 1400 1200 1650 2000 1370 1700 1650 1680
Centrifugal Fan Type 250 280 280 355 400/450 400 450/500 500/560 560)630
Max RPM 4750 4180 4180 3400 2800 3100 2400 2100 1900
Max Power KW 4.6 6.33 6.33 12.7 17.3 12.7 21.3 21.3 34.5
Max motor size 112M 132S 132S 160M 160M 160M 160L 160L 200L
Static pres. Pa 2200 1950 1890 2230 2600 2065 2345 2285 2330
Cooling medium(1) R404A (R407C /R134A/R22/other second refrigerant)
Heating medium(1) Steam, hot water, or electric
Humidifying medium(1) Steam, fresh water + compressed air, or fresh water
Power Supply 3Ph, 440/380 V, 60750Hz
Dimension (mm) Width (W) 1027 1027 1417 1417 1417 1947 1947 1947 1947
Height (H) 1384 1634 1384 1634 2034 1634 1834 2184 2484
Length(2)(L) 2457 2937 2617 2777 3257/3417 2857 2857/2937 3017/3177 3177/3337
Weight kg -1400 -1450 -1450 -1500 -1550 -1550 -1600 -1650 -1700
(1) Design condition:          
Cooling, heating, and humidifying condition is defined according to clients specification.          
(2) The length is just one solution from all possible arrangements for guidance, and other possibilities are available.          
(3) The larger external static pressure of AHU is available if using enhanced fan bearings.          