Description
Marine split air conditioner is the approved product applied to special vessel application based on marine cabinet air conditioner. The split systems are a matched combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires. The fan coil is mounted on the wall, near the ceiling. This selection of fan coils permits inexpensive and creative solutions to design problems such as:
➽ Add ons to current space (an office or family room addition).
➽ Special space requirements.
➽ When changes in the load cannot be handled by the existing system.
➽ When adding air conditioning to spaces that are heated by hydronic or electric heat and have no duct work.
➽ Historical renovations or any application where preserving the look of the original structure is essential.
Features
● Low sound levels
When noise is a concern, the duct--free split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through duct work.
● Secure operation
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through duct work. In addition, these units can be installed close to an outside wall, coils are protected from vandals and severe weather.
● Fast installation
This compact duct--free split system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes these duct--free split systems the equipment of choice, especially in retrofit situations.
● Simple serving and maintenance
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw--thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent. On all indoor units, service and maintenance expense is reduced due to easy--to--use cleanable filters. In addition, these high wall systems have extensive self--diagnostics to assist in troubleshooting.
Technical Data
Model |
KFR-25GW/M |
KFR-35GW/M |
KFR-51GW/M |
KFR-72GW/M |
KFR-80GW/M |
KFR-90GW/M |
Power souce |
220-240V / 50Hz-60Hz |
220-240V / 50Hz-60Hz |
220-240V / 50Hz-60Hz |
220-240V / 50Hz-60Hz |
220-240V / 50Hz-60Hz |
220-240V / 50Hz-60Hz |
Horsepower(P) |
1 |
1.5 |
2 |
3 |
3.5 |
4 |
Capacity (BTU) |
9000BTU |
12000BTU |
18000BTU |
24000BTU |
30000BTU |
36000BTU |
Cooling capacity |
2500W |
3496W |
5100W |
7200W |
7600W |
8800W |
Cooling powet input |
820W |
1160W |
1650W |
2200W |
2450W |
3220W |
Heating capacity |
2550W |
3530W |
5000W |
7000W |
7700W |
9000W |
Heating powet input |
860W |
1230W |
1600W |
2100W |
2250W |
3100W |
Current input |
4.2A |
5.9A |
7.8A |
9.8A |
11.5A |
13.8A |
Air Flow Volume(M3/h) |
450 |
550 |
900 |
950 |
1350 |
1500 |
Ratde current input |
5.9A |
7.9A |
12.3A |
13 |
18.5A |
21A |
Indoor/Ourdoor noise |
30~36/45db(A) |
36~42/48db(A) |
39~45/55db(A) |
42~46/55db(A) |
46~51/56db(A) |
48~53/58db(A) |
Compressor |
GMCC |
GMCC |
GMCC |
GMCC |
GMCC |
GMCC |
Refrigerants |
R22/520g |
R410A/860g |
R410A/1500g |
R410A/1650g |
R410A/2130g |
R410A/2590g |
Pipe diameter |
6.35 / 9.52 |
6.35 / 12.7 |
6.35 / 12.7 |
9.52 / 15.88 |
9.52 / 15.88 |
9.52 / 15.88 |
Weight |
9/29KG |
11/35KG |
13/43KG |
14/54KG |
18/58KG |
20/72KG |